Single Phase Induction Type Energy Meter
Single phase induction type energy meters are extensively
used for the measurement of electrical energy in single phase A.C circuits. One
can find such meters installed in homes. It is also called as single phase
watt-hour meter.
Principle: torque is produced to rotate the disc is due to interaction
of two fluxes. Since the e.m.f induced in the disc by induction, this
instrument operates on A.C only.
Construction: The below fig shows the various parts of a single phase induction
type energy meter. It consists of a shunt magnet, a series magnet, a rotating
disc, a brake magnet and a counting mechanism.
The shunt magnet consist of a number of M shaped iron
laminated core wound with a fine wire of many turns i.e. coils and is connected
across the supply. The shunt coil carries a current proportional to supply
voltage and is known as Pressure coil.
The flux produced by shunt magnet lags behind the supply voltage by 90o due to coil inductance. The series magnet consist of U shaped laminated core wound with a few turns of heavy gauge wire and is connected in series with the load and carries the load current. The wound coil is known as current coil.
The flux produced by shunt magnet lags behind the supply voltage by 90o due to coil inductance. The series magnet consist of U shaped laminated core wound with a few turns of heavy gauge wire and is connected in series with the load and carries the load current. The wound coil is known as current coil.
A thin aluminium disc is mounted on a spindle between the two
magnets so that it interacts with the fluxes of both the magnets. Copper shading
ring is placed on central limb of the shunt magnet to adjust lagging of shunt
coil flux behind the voltage by 90o. It is also termed as quad band
or lag adjuster or P.F compensator. Control springs are fixed to the spindle of
the disc which provides controlling torque.
The braking magnet is of C shaped magnet which provides
braking torque when the aluminium disc is in motion. The braking magnet
rotates, eddy currents re induced in it due to flux produced by braking magnet.
The eddy currents opposes the disc rotation (according to Lenz’s law). The number
of revolutions of the disc is a measure of the electrical energy consumed by
the load and is recorded on dial which are geared to the spindle (i.e.
recording mechanism).
Working: When the energy meter is connected in the circuit, the pressure coil
carries current proportional to the supply voltage, whereas the series coil
carries the load current. The series magnet produces the flux Φ1,
which is in phase with the load current I. similarly the shunt magnet produces
the flux Φ2, which is lagging behind the voltage by 90o.
The two fluxes Φ1 and Φ2 induces an emfs (e1
and e2) in the disc which further produce the eddy currents (i1
and i2). These eddy currents i1 and i2 setup
by the respective induced emfs are in phase with the corresponding emfs. The interaction
between the fluxes and eddy current produces the driving force which results
the disc to rotate.
The breaking torque (controlling torque) is provided by the
braking magnet, and by adjusting position of this magnet, desired speed per
unit can be obtained.
Single phase induction type energy meter is also popularly known as watt-hour meter.